Recent activity in Sensors and Industrial Instrumentation

1 1 vote
1 1 answer
Which of the following statements is/are correct for a thermocouple?It is based on the Seebeck Effect.The change in resistance is measured.The voltage difference between ...
0 0 votes
1 1 answer
Active strain gauges are connected in a half-bridge configuration to measure strain in a cantilever element. When powered by a voltage source of $10$ $\mathrm{V}$, the vo...
0 0 votes
1 1 answer
A glass $\mathrm{pH}$ electrode behaves linearly with an output change of $60$ $\mathrm{mV}$ per unit change in $\mathrm{pH}$. The measurement reference is set such that ...
0 0 votes
0 0 answers
A photodiode has a responsivity $0.8 \mathrm{~A} / \mathrm{W}$. If the input optical power to the photodiode is $2$ $\mathrm{mW}$, the power delivered to a $50 \: \Omega$...
0 0 votes
0 0 answers
A current carrying semiconductor of thickness $0.7$ mm is placed in a transverse magnetic field. The measured Hall voltage is $0.9$ $\mathrm{mV}$ and the current is $6$ $...
0 0 votes
0 0 answers
The emitted radiant energy from a piece of metal was measured using a pyrometer. The temperature was calculated to be $1000^{\circ} \mathrm{C}$, assuming a surface emissi...
0 0 votes
0 0 answers
A parallel plate capacitive displacement sensor has a plate area of $2 \mathrm{~cm}^{2}$. The air gap between the plates is decreased by $0.1$ mm from an initial value of...
0 0 votes
1 1 answer
Consider the readout circuit of a piezoelectric sensor shown in the figure.When the piezoelectric sensor generates a charge $q_{p}$, the resulting change in voltage $\mat...
0 0 votes
0 0 answers
A shielded cable with $\mathrm{C}_{\text {stray }}=20 \mathrm{~pF}$ and $\mathrm{R}_{\text {wire }}=10 ~\Omega$ is used to connect the inductive sensors as shown in the f...
0 0 votes
0 0 answers
Consider the capacitive sensor circuit and its output voltage shown in the figure. The circuit is switched $\mathrm{ON}$ at $\mathrm{t}=0$. Assuming the opamp to be ideal...
0 0 votes
0 0 answers
​Consider an ultrasonic measurement system shown in the figure. The ultrasonic transmitter $(T)$ sends a continuous wave signal $x(t)=\cos \left(2 \pi f_{1} t\right)$ vol...
0 0 votes
0 0 answers
A linear potentiometer $(0-10 \mathrm{k} \Omega)$ is used to measure the water level as shown in the figure. The resistance between $\mathrm{A}$ and $\mathrm{C}$ varies l...
0 0 votes
0 0 answers
A linear transducer is calibrated for the ranges shown in the figure. The gain of the transducer is $\_\_\_\_\_$ $\mathrm{mA} /{ }^{\circ} \mathrm{C}$ (rounded off to two...
0 0 votes
0 0 answers
The resistance of a thermistor is measured to be $2.25 \: \mathrm{k} \Omega$ at $30^{\circ} \mathrm{C}$ and $1.17 \: \mathrm{k} \Omega$ at $60^{\circ} \mathrm{C}$. Its ma...
0 0 votes
0 0 answers
An air filled parallel plate electrostatic actuator is shown in the figure. The area of each capacitor plate is $100 \: \mu \mathrm{m} \times 100 \: \mu \mathrm{m}$. The ...
0 0 votes
0 0 answers
A metallic strain-gauge $(\mathrm{SG})$ with resistance $R_{\mathrm{SG}}$ is connected as shown in the figure, where $R_{\mathrm{L} 1}, R_{\mathrm{L} 2}, R_{\mathrm{L} 3}...
0 0 votes
0 0 answers
Match the following sensors with their most suitable applications.$$\begin{array}{|l|l|l|l|} \hline & \textbf{Sensor} & & \textbf{Application} \\ \hline \text{P} & \text{...
0 0 votes
0 0 answers
In the force transducer shown in Figure (a), four identical strain gauges $S1, S2, S3$, and $S4$ are mounted on a cantilever at equal distance from its base. $S1$ and $S2...
0 0 votes
0 0 answers
The primary coil of a linear variable differential transformer (LVDT) is supplied with AC voltage as shown in the figure. The secondary coils are connected in series oppo...
0 0 votes
0 0 answers
The working of the hand-held metal detector most widely used by security personnel for human frisking is based on the principle ofchange in reluctance of an iron core in ...
0 0 votes
0 0 answers
Which of the following flow meters offers the lowest resistance to the flow? Turbine flow meter Orifice flow meter* Venturi meter Electromagnetic flow meter
0 0 votes
0 0 answers
A pneumatic nozzle-flapper system is conventionally used to convert __________Small changes in flapper’s velocity to large changes in output temperatureSmall changes in f...
0 0 votes
0 0 answers
The figure shows a Chromel-Alumel thermocouple, where the junction $A$ is held at temperature $T_{A},$ and a thermal emf $E_{1}$ is measured using an ideal voltmeter betw...
0 0 votes
0 0 answers
Input-output characteristic of a temperature sensor is exponential for aThermistorThermocoupleResistive Temperature Device $\text{(RTD)}$Mercury thermometer
0 0 votes
0 0 answers
A piezoresistive pressure sensor has a sensitivity of $\text{1 (mV/V) /kPa}$. The sensor is excited with a $\text{dc}$ supply of $\text{10 V}$ and the output is read usin...
0 0 votes
0 0 answers
A strain gage having nominal resistance of $1000\:\Omega$ has a gage factor of $2.5$. If the strain applied to the gage is $100\:\mu m/m$, its resistance in ohm will chan...
0 0 votes
0 0 answers
A $\text{J}$-type thermocouple has an output voltage $V_{\theta }=\left ( 13650+50\: \theta _{x} \right ) \mu \;V$, where $\theta _{x}$ is the junction temperature in Cel...
0 0 votes
0 0 answers
For the full bridge made of linear strain gages with gage factor $2$ as shown in the diagram, $R_{1}=R_{2}=R_{3}=R_{4}=100 \:\Omega$ at $0^{\circ}C$ and strain is $0$. Th...
0 0 votes
0 0 answers
Four strain gauges in a Wheatstone bridge configuration are connected to an instrumentation amplifier as shown in the figure. From the choices given below, the preferred ...
0 0 votes
0 0 answers
Thermocouples measure temperature based on Photoelectric effectSeebeck effectHall effectThermal expansion
0 0 votes
0 0 answers
A differential capacitive sensor with a distance between the extreme plates $100\;mm$ is shown in figure below. The difference voltage $\Delta V=V_1-V_2,$ where $V_1$ and...
0 0 votes
0 0 answers
​​​​​​Four identical resistive strain gauge factor of 2.0 used in a wheatstone bridge as shown in the figure below. Only one of the strain gauges R${_S}{_E}{_N}{_S}{_E}$ ...
0 0 votes
0 0 answers
A 100 W light source emits uniformly in all directions. A photodetector having a circular active area whose diameter is 2 cm is placed 1 m away from the source, normal to...
0 0 votes
0 0 answers
A piezoelectric transducer with sensitivity of 30 m V/kPa is intended to be used in the range of 0 kPa to 100 kPa. The readout circuit has a peak noise amplitude of 0.3 m...
0 0 votes
0 0 answers
A $1000\;\Omega$ strain gage $(R_g$) has a gage factor of $2.5$. It is connected in the bridge as shown in figure. The strain gage is subjected with a positive strain of ...
0 0 votes
0 0 answers
The average velocity $v$ of flow of clear water in a $100\; cm$ (inner) diameter tube is measured using the ultrasonic flow meter as shown in the figure. The angle $\thet...
0 0 votes
0 0 answers
As shown in the figure, temperature $\theta$ is measured using a $K$ type thermocouple. It has a sensitivity of 40 $\mu V/^{\circ}C$. The gain $(G)$ of the ideal instrume...
0 0 votes
0 0 answers
A piezoelectric pressure sensor has a bandpass characteristic with cut-off frequencies of 0.1 Hz and 1 MHz, and a sensitivity of 100 mV/kPa. The sensor is subjected to a ...
0 0 votes
0 0 answers
The hot junction of a bare thermocouple, initially at room temperature $(30^\circ{C})$, is suddenly dipped in molten metal at $t=0$ $s$. The cold junction is kept at room...
0 0 votes
0 0 answers
The junction semiconductor temperature sensor shown in the figure is used to measure the temperature of hot air. The output voltage $V_\circ$ is $2.1\;V$. The current out...
To see more, click for all the questions in this category.